16
Operational
Depth of Scan Field:
76mm to 254mm (3" to 10")
Scan Speed:
Model 770: 2000 scan lines per second
Model 775: 1200 scan lines per second
Scan Pattern:
Model 770: Omnidirectional
(20 interlocking lines)
Model 775: 12-line raster
Indicators:
LED: green = laser on; red = good read
Beeper Operation:
Selection of 3 tones for “Good Read”
Maintenance Required:
Clean window periodically
Decode Capability:
Autodiscriminates
System Interfaces:
RS232C; Light Pen Emulation; OCIA
Optional:
Opto coupled 6 amps US and Canada, 5 amps
EEA countries TRIAC output; object sensor input
Print Contrast:
35% minimum reflectance difference
Roll, Pitch, Yaw:
360
E, 60E, 60E
Environmental
Storage Temperature:
-40
EC to 60EC (-40EF to 140EF)
Operating Temperature:
0
EC to 35EC (32EF to 95EF)
Humidity:
5% to 95% relative humidity, non-condensing
Light Levels:
Up to 3200 foot candles - works in direct sun
Ventilation:
None required
Shock:
100g for 1ms
ESD:
8 kV IEC 801-2
Contaminants:
Protects against dust, falling dirt, and dripping
non-corrosive liquid