beautypg.com

Wiring, Warning – Maytag Thru-the-Wall Room Air Conditioner User Manual

Page 5

background image

5

1. Remove the grille and filter from the front panel (Figure

10). Doing one side at a time, press the tab on the front

panel (Figure 10) with one hand while lifting the grille

with the other.

Figure 10

2. Using the four washer head sheet metal screws pro-

vided, mount the front panel to the chassis through the

front panel mounting holes (Figure 11).

Mounting

Holes

Front

Panel

Chassis

Mounting

Holes

Mounting

Holes

Figure 11

3. Reattach the filter and front grille. Place the supplied

knobs onto the proper stem (Figure 12).

Knobs

Figure 12

IMPORTANT NOTES:

1. The unit is equipped with a rubber-grommet-mounted

compressor. These grommets are factory set and

require no adjustment.

2. Obstruction to air flow must be checked and removed.

Check the indoor and outdoor grilles for obstructions.

The unit must be located where curtains, furniture,

trees, or other objects do not block air flow to and from

the unit. If air is obstructed and/or deflected back into

the unit, the air conditioner’s compressor may cycle on

and off rapidly. This could cause damage to the

compressor.

Wiring

Before wiring the unit, please review the following warnings
and cautions.

WARNING

To avoid property damage, personal injury
or death due to electrical shock, do not
service this unit without first shutting off
power to the unit from the circuit breaker
and/or removing the unit cord set plug
from the wall outlet.

WARNING

To avoid the risk of property damage,
personal injury or electrical shock, do not
use an extension cord with this unit.

WARNING

To avoid the risk of fire, property damage,
or personal injury, use only copper
conductors.

WARNING

To avoid the risk of personal injury, wiring
to the unit must be properly polarized and
grounded.