3. volt-ampere curves – Miller Electric XLT 135 User Manual
Page 15
OM-198 076 Page 11
2-3. Volt-Ampere Curves
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding power source. Curves
of other settings fall between the
curves shown.
ssb1.1 10/91 − 196 608 / 196 609
A. 115 VAC Model
B. 230 VAC Model
0.0
5.0
10.0
15.0
20.0
25.0
30.0
0
10
20
30
40
50
60
70
80
90 100 110 120 130 140 150 160
LOAD AMPS
OUTPUT VOL
TS
Range 4
Range 3
Range 2
Range 1
0.0
5.0
10.0
15.0
20.0
25.0
30.0
0
10
20
30
40
50
60
70
80
90 100 110 120 130 140 150 160 170 180 190 200
LOAD AMPS
OUTPUT VOL
TS
Range 4
Range 3
Range 2
Range 1
This manual is related to the following products: