Abbreviations – Motion Actuator User Manual
Page 22

TERM
DESCRIPTION OF TERM
Electrical time
constant
Electrical time constant is the time taken for a step current input to the motor to reach 63.2% of its
value.
Continuous
working voltage
Continuous working voltage is the maximum allowable continuous voltage between any two motor
phases or between any motor phase and the motor safety earth.
Pole pitch
Pole pitch is the distance in millimetres for one complete electrical cycle (between like magnetic
poles).
Power dissipation
Power dissipation is the maximum power that can be dissipated by the motor when the motor
phases are at their maximum operating temperature, the ambient temperature is 25°C, the motor
is not moving and there is no forced cooling. It is quoted with and without the addition of a 25 x 25
x 2.5cm heatsink plate mounted with thermal grease to the mounting surface of the motor.
Maximum phase
temperature
Maximum phase temperature is the maximum operating temperature for the motor phases. It is
limited to provide a safe operating temperature for the magnets.
R
thphase-houslng
R
thphase-houslng
is the temperature rise from the motor housing to the motor phases for an input
power of 1 watt to the motor. The motor is not moving, there is no forced cooling and no additional
heatsinking.
R
thhousing-ambient
R
thhousing-ambient
is the temperature rise from ambient temperature to the motor housing for an input
power of 1 watt to the motor. The motor is not moving and there is no forced cooling. It is quoted
with and without the addition of a 25 x 25 x 2.5cm heatsink plate mounted with thermal grease to
the mounting surface of the motor.
Thermal time
constant
Thermal time constant is the time taken for the motor phases to cool to 36.8% of the difference
between motor phase and ambient temperatures when there is no current flowing, the motor is not
moving there is no forced cooling and no additional heatsinking.
ABBREVIATIONS
The abbreviations used in this Guide are listed in the following table.
A
pk
Ampere peak
PCB
Printed circuit board
A
rms
Ampere root mean square
PUR
Polyurethane
AWG
American Wire Gauge
PVC
Poly Vinyl Chloride
COS
cosine
s
second
d.c.
direct current
SIN
sine
EMC
Electro-Magnetic Compatibility
TYP
Typical
EMF
Electro-Motive Force
UL
Underwriters Laboratory
kg
kilogramme
V
Volt
m
metre
V
pk
Volt peak
mA
milliampere
V
pk-pk
Volt peak to peak
mH
millihenry
V
rms
Volt root mean square
mm
millimetre
W
Watt
MTG
Mounting
°C
degrees Celsius
N
Newton
mm
micrometre (micron)
PTC
Positive Temperature Coefficient
Page 16
Appendices