beautypg.com

Electrical connection 73, Electrical connection – Miele H4890BP2 User Manual

Page 73

background image

,

CAUTION: Before servicing,

disconnect the power supply by
either removing the fuse, shutting off
the power main or manually
"tripping" the circuit breaker.

Installation work and repairs should
only be performed by a qualified
technician in accordance with all
applicable codes and standards.
Repairs and service by unqualified
persons could be dangerous and
the manufacturer will not be held
responsible.

Before connecting the appliance to
the power supply, make sure that
the voltage and frequency listed on
the data plate correspond with the
household electrical supply. This
data must correspond to prevent
machine damage. Consult an
electrician if in doubt.

Only operate the appliance after it
has been installed into cabinetry.

Installer:
Please leave these instructions with
the consumer.

Power supply

The oven is equipped with a 6 ft.
(1.8 m) flexible power cord consisting
of 4 wires ready for connection to a
dedicated 3 pole, 4 wire grounded
power supply:

240 V, 60 Hz, 40 A fuse rating

or

208 V, 60 Hz, 40 A fuse rating

Black wire: connect to L1 (hot)

Red wire:

connect to L2 (hot)

White wire: connect to N (neutral)

Green wire: connect to GND (ground)

A dedicated line and junction box
should be used to connect the oven to
a 40 A circuit.

Connection details are also given on the
diagram located on the top of the oven.

Data plate

The silver data plate is located along
the front side of the lower oven with the
door open.

Electrical connection

73