UIDE

The following guide is for reference purposes only. Contact a Metrologic
representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited
warranty terms.

All Interfaces

IS6520/MS6520 Series Troubleshooting Guide

SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

No LEDs, beep
or motor spin

No power is being
supplied to the
scanner

Check transformer, outlet and
power strip. Make sure the cable
is plugged in to the scanner

No LEDs, beep

No power is being
supplied to the
scanner front host

Some host system’s cannot
supply enough current to power
Omni-Quest. Use the power
supply included with the scanner.

3 beeps on
power up

Non-volatile RAM
failure

Contact a Metrologic
Representative, if the unit will not
hold the programmed
configuration

Continuous
razz tone on
power up

RAM or ROM failure

Contact a Metrologic
Representative, if the unit will not
function

Razz tone and
green LED
flash at power
up

VLD failure

Contact a Metrologic
Representative

Razz tone and
both LEDs
flash at power
up

Scanner motor failure

Contact a Metrologic
Representative

Unit scans,
Communicates
and beeps
twice

Same symbol timeout
set too short

Adjust same symbol timeout for a
longer time