Height of Restriction (X)

Minimum Depth of Fireplace/Firebox

No restriction

13

1

/

4

"

0 to 1.5"

16"

Greater than 1

1

/

2

" to 3"

16"

Greater than 3:

ANY BARRIER GREATER THAN THREE INCHES (3")
PLACED IN FRONT OF THE GAS LOG SET IS NOT
RECOMMENDED BY THE MANUFACTURER.

PLACEMENT IN A FIREPLACE WITH A RESTRICTIVE BARRIER

IMPORTANT INFORMATION FOR THE INSTALLATION OF THIS GAS LOG SET

The following are guidelines for placing a gas log set in a fireplace that has a restrictive barrier along the bottom front
opening of the fireplace. Some examples of barriers are glass/screen door frames and sunken/recessed fireplaces.

Barriers such as the bottom of a glass door frame placed in
front of a gas log set can change the air flow characteristics
of the fireplace which in turn can cause the unit to overheat
and malfunction.

Glass door frames

with adjustable

louvers should have

the lovers fully open

while the unit is in

operation.

Height of restrictive barrier

caused by glass door frames,

recessed fireplaces, etc. from the

base or bottom surface of the

unit.

(Refer to Table).

The log set should be
placed against or as near
as possible to the rear wall
of the fireplace/firebox.

Depth of fireplace/firebox.

(Refer toTable).

Figure 3 - Reference Drawing of a Natural Flame Log Set in an Enclosure

NOTE: Non combustible material such as refractory brick may be used to line the floor of the fireplace
in order to raise the height of the gas log set in relation to a restrictive barrier. If the unit is raised, the
minimum height dimension listed in the homeowner’s manual must not be exceeded.

NOTE: If the log set is equipped with a remote receiver, a restrictive barrier may reduce the battery life
by increasing the ambient temperature inside the fireplace. Placement of the receiver outside of the
fireplace will extend the battery life.