Motorola LD-W-1 User Manual
Page 14
LD-G-1 / LD-W-1
English
Page 31
§
Standard or second velocity characteristics
§
Shunting gear active or inactive
§
Fast, medium or slow acceleration and brake delay
The setting of the delay can be combined with any setting of the
velocity characteristic and the shunting gear.
The setting is made by attaching solder bridges to X17 (on the front of
the decoder, underneath the IC U1) and to X20 (on the front of the
decoder, to the left of IC U1). The assignment is as follows:
Connection
Operation
X17 Pin 1: no solder bridge
Standard velocity characteristic +
shunting gear active, switched via F4
X17 Pin 1 - X 20
Second velocity characteristic +
shunting gear inactive
X17 Pin 1 - X 17 Pin 2
Standard velocity characteristic +
shunting gear inactive
X17 Pin 3: no solder bridge
Fast delay
X17 Pin 3 - X 20
Slow delay
X17 Pin 3 - X 17 Pin 2
Medium delay
Example:
Adjusting the second velocity
characteristic and the medium
acceleration and brake delay
Setting the locomotive address
The locomotive decoder can be set to one of 255 addresses. The
setting is made by mounting solder bridges to X13 - X17 (on the front
of the decoder, left of the IC U1) resp. X18 on the front of the decoder,
right of the IC U1). The assignment is shown in the list on page 68.
The solder pads are numbered from the left side of the PCB as follows:
1
2
3