Product specifications – Maytag HRX40DERS User Manual
Page 6
* Standard element wattages are shown. Other element wattages (up to the maximum shown) are available when specified.
** Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local
electrical code.
6
Product Specifications
Model
HRX30DERT HRX40DERS HRX40DERT HRX52DERS
Tank Capacity
In Gallons
30
40
40
50
*Element
Upper
5500
5500
5500
5500
Wattage
at 240 Volt
Lower
5500
5500
5500
5500
Recovery Rate
Upper
25
25
25
25
In Gals Per Hr.
@ 90°F Rise
Lower
25
25
25
25
Diameter
19
″
21
1
⁄
2
″
19
″
23
″
Height
47
″
46
″
60
″
49
″
Maximum Fuse or
Circuit Breaker Size
30
30
30
30
**Minimum
Wire Size (Gauge)
10
10
10
10
Model
HRX52DERT HRX66DERT HRX82DERT
Tank Capacity
In Gallons
50
66
80
*Element
Upper
5500
5500
5500
Wattage
at 240 Volt
Lower
5500
5500
5500
Recovery Rate
Upper
25
25
25
In Gals Per Hr.
@ 90°F Rise
Lower
25
25
25
Diameter
21
1
⁄
2
″
23
″
25
″
Height
61
″
61
″
61
1
⁄
2
″
Maximum Fuse or
Circuit Breaker Size
30
30
30
**Minimum
Wire Size (Gauge)
10
10
10