Ss38 direct vent gas stove, Venting installation, St1112 vert vent – Monessen Hearth SS38 User Manual
Page 19

19
46D0232
SS38 Direct Vent Gas Stove
H
V
H
1
ST1111
vert vent 2 elbows
Figure 24 -
Vertical Rigid Venting Configuration Using Three
90° Elbows with Two Horizontal Runs
VENTING INSTALLATION
NOTE: Install restrictor
into 4" collar of stove
or first vent secton as
shown.
Table 6 - Vertical Venting with Two (2) Elbows
Vertical (V)
Horizontal (H) + (H
1
)
Minimum
Maximum
8'
2'
9'
4'
10'
6'
11'
8'
23'
8'
H
V
1
V
V
ST1112
vert vent
Table 7 - Vertical Venting with Two (2) 90°
Elbows
Vertical (V) + (V
1
) Horizontal (H) + (H
1
)
Minimum
Maximum
8'
2'
9'
12'
10'
18'
11'
20'
NOTE: Install
restrictor into 4"
collar of stove or
first vent secton as
shown.
NOTE: Install
restrictor into
4" collar of
stove or first
vent secton as
shown.
ST1112
Figure 26 -
Vertical Rigid Venting Configuration
with No Horizontal run
Vertical Venting
V = 40' maximum
Figure 25 -
Vertical Rigid Venting Configuration Using