Monte Carlo Fan Company 5YM52 User Manual
Page 3
Tighen 2 downrod set screws and then
tighen lock nuts.
Align hole in downrod with hole in
yoke and install cross pin.
Install keeper pin into cross pin.
Loosen 2 screws and remove pin
with keeper for downrod, yoke cover,
and canopy to fit in yoke of fan.
10
12
13
Install downrod into yoke.
11
14
Thread black wire, white wire, blue
wire and safety cable through down-
rod.
9
Lift mounting neck to mounting Plate
and align screws.
7
Secure mounting neck to the mount-
ing plate with four screws to become
a complete mounting bracket.
8
For Canadian installation in both flush and
downrod mode the safety cable must be
installed into the house structure beams using
the 3” lag screws provided. Make sure that
when the safety cable is fully extended the
leadwires are longer than the cable and no
stress is placed on the leadwires.
16
Canadian mounting only
Safety Cable
Lag Screw
Make wire connections to power source using
wire nuts provided. Make sure that no filiments
are outside of the wirenut. After making the
wire connections, the wires should be spread
apart with the grounded conductor and the
equipment-grounding conductor on one side of
the outlet box and ungrounded conductor on
the other side of the outlet box.
18
Re-install safety bar removed in
step. 3 by placing safety bar on
screws, sliding into place, and tight-
ening the 2 screws.
15
For pul chain controls, follow diagram above.
Make sure that all exposed wiring is secured
inside wire nuts. Note: Wires from house may
vary in color and may not include ground wire.
After wiring is complete, gently push wires into
junction box with wire nuts pointing upward.
Refer to point 3 of safety tips.
17
House
Fan
Black
White
Green
Black
White
Green(downrod)
Green(Bracket)
Blue