beautypg.com

Monessen, Hpba, Vented gas logs – Monessen Hearth VWF24 User Manual

Page 4

background image

To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the
product and all applicable building or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this
brochure are for illustrative purposes only and are not intended for, nor should they be used as a substitute for the instructions packaged with the unit. Appearance and specifications of the
product are subject to change without notice. © 2008 Monessen Hearth Systems Co.

A Brand of Monessen Hearth Systems Co.
149 Cleveland Drive, Paris, Kentucky 40361

www.monessenhearth.com

Ver.02 MON9508

Monessen

Your Monessen Dealer:

HPBA

Hearth, Patio & Barbecue Association

MADE IN U.S.A.

Classic

Colossal

Manual Control

Manual SPK Control

Millivolt Control / HI-LOW

Radiant

Series

Series

Fuel

Minimum Hearth Area

Minimum Hearth Area

Minimum Hearth Area

Heat

Model

Log Size Log Size* Type

Front

Depth Back

Height Front

Depth Back

Height Front

Depth Back

Height BTU/H

Output

CSA VENTED GAS LOGS REFRACTORY

VWF18

18”

24”

NG

-

-

-

-

24

13 1/2” 21”

16”

28”

13 1/2” 25”

16”

60,000

14,000

VWF18 18”

24”

LP

-

-

-

-

24

13 1/2” 21”

16”

28”

13 1/2” 25”

16”

60,000

14,000

VWF24 24”

30”

NG

-

-

-

-

30

13 1/2” 27”

16”

34”

13 1/2” 31”

16”

70,000

16,000

VWF24

24”

30”

LP

-

-

-

-

30

13 1/2” 27”

16”

34”

13 1/2” 31”

16”

60,000

14,000

VWF30

30”

36”

NG

-

-

-

-

36

13 1/2” 33”

16”

40”

13 1/2” 37”

16”

80,000

18,000

VWF30

30”

36”

LP

-

-

-

-

36

13 1/2” 33”

16”

40”

13 1/2” 37”

16”

60,000

14,000

VWF36

36”

-

NG

-

-

-

-

42

13 1/2” 39”

16”

46”

13 1/2” 41”

16”

90,000

22,000

VWF36

36”

-

LP

-

-

-

-

42

13 1/2” 39”

16”

46”

13 1/2” 41”

16”

60,000

14,000

VWF18ST

18”

-

NG

-

-

-

-

-

-

-

-

28”

16”

28”

16”

60,000

14,000

VWF18ST

18”

-

LP

-

-

-

-

-

-

-

-

28”

16”

28”

16”

60,000

14,000

VWF24ST

24”

-

NG

-

-

-

-

-

-

-

-

34”

16”

34”

16”

70,000

16,000

VWF24ST

24”

-

LP

-

-

-

-

-

-

-

-

34”

16”

34”

16”

60,000

14,000

RADCO VENTED GAS LOGS

VWF18

18”

24”

NG

22”

13”

19”

16”

24”

13 1/2” 21”

16”

28”

13 1/2” 25”

16”

80,000

18,000

VWF18

18”

24”

LP

22”

13”

19”

16”

24”

13 1/2” 21”

16”

28”

13 1/2” 25”

16”

60,000

14,000

VWF24

24”

30”

NG

28”

13”

25”

16”

30”

13 1/2” 27”

16”

34”

13 1/2” 31”

16”

90,000

20,000

VWF24

24”

30”

LP

28”

13”

25”

16”

30”

13 1/2” 27”

16”

34”

13 1/2” 31”

16”

60,000

14,000

VWF30

30”

36”

NG

34”

13”

31”

16”

36”

13 1/2” 33”

16”

40”

13 1/2” 37”

16”

90,000

22,000

VWF30

30”

36”

LP

34”

13”

31”

16”

36”

13 1/2” 33”

16”

40”

13 1/2” 37”

16”

60,000

14,000

VWF36

36”

-

NG

38”

13”

37”

16”

42”

13 1/2” 39”

16”

46”

13 1/2” 41”

16”

90,000

22,000

VWF36

36”

-

LP

38”

13”

37”

16”

42”

13 1/2” 39”

16”

46”

13 1/2” 41”

16”

60,000

14,000

VWF18ST

18”

-

NG

24”

16”

20”

16”

24”

16”

24”

16”

28”

16”

28”

16”

80,000

18,000

VWF18ST

18”

-

LP

24”

16”

20”

16”

24”

16”

24”

16”

28”

16”

28”

16”

60,000

14,000

VWF24ST

24”

-

NG

28”

16”

26”

16”

30”

16”

30”

16”

34”

16”

34”

16”

90,000

20,000

VWF24ST

24”

-

LP

28”

16”

26”

16”

30”

16”

30”

16”

34”

16”

34”

16”

60,000

14,000

Manual Control

Millivolt Control

Radiant

Fuel

Minimum Hearth Area

Minimum Hearth Area

Heat

Model

Log Size Type

Front

Depth Back

Height Front

Depth Back

Height BTU/H

Output

VENTED GAS LOGS

FIBER

NBV24N–N24F/LG24F

24"

NG

26"

13 1/2" 17"

16"

26"

13 1/2" 18"

16"

50,000

15,000

NBV24P–N24F/LG24F

24"

LP

26"

13 1/2" 17"

16"

26"

13 1/2" 18"

16"

50,000

15,000

NBV30N–N30F/LG30F

30"

NG

32"

13 1/2" 23"

16"

32"

13 1/2" 24"

16"

65,000

17,000

NBV30P–N30F/LG30F

30"

LP

32"

13 1/2" 23"

16"

32"

13 1/2" 24"

16"

65,000

17,000

Millivolt Control

Fuel

Minimum Hearth Area

BTU/H

Model

Log Size Type

Front

Depth Back

Height NG

LP

VENTED GAS LOGS

FIBER

TPB18

18"

NG/LP 26"

13"

18"

17"

28,000

28,000

TPB24

24"

NG/LP 29"

13"

22 1/4" 17"

38,000

34,000

TPB30

30"

NG/LP 33"

13"

25 1/4" 17"

38,000

34,000

*When using Colossal Series Split River Oak and Weathered Pine
logs, use the burner specifications for the millivolt control for all
installations when sizing for minimum hearth area.

Vented Gas Logs