These ‘C’ Channel brackets are installed in the vertical
plane using existing screws (Item 6) to support these ‘C’
Channels using the upper and lower Key Hole openings in
the ‘C’ Channels. The ‘C’ Channels are identical and once
installed will allow ample amounts of air through the cooling
fan mounted on the rear side of the oven by keeping the
oven away from the rear wall.

If you have any questions about how to mount these two
‘C’ Channel brackets, kindly phone

Middleby Technical

Services at 847-741-3300. Press 3, then 5 for Technical

Support.

III. ELECTRICAL CONNECTION INFORMATION

FOR PS528-SERIES OVENS.

WARNING

Authorized supplier personnel normally accom-

plish the connections for the ventilation system,

electric supply, as arranged by the customer.

Following these connections, the factory-autho-

rized installer can perform the initial startup of

the oven.

Check the oven data plate (Figure 2-10) before making any

electric supply connections. Electric supply connections

must agree with data on the oven data plate.
NOTE: The electric supply installation must satisfy the

requirements of the appropriate statutory authority, such

as the National Electrical Code (NEC), ANSI/NFPA70,

(U.S.A.); the Canadian Electrical Code, CSA C22.2; the

Australian Code AG601; or other applicable regulations.

A fused disconnect switch or a main circuit breaker

(customer furnished) MUST be installed in the electric

supply line for each oven; it is recommended that this

switch/ circuit breaker have lockout/tagout capability. The

electric supply connection must meet all national and local

electrical code requirements. Copper is the recommended

material for the electrical supply conductors.

IV. ELECTRIC SUPPLY FOR

ELECTRICALLY HEATED OVENS

Power requirements for electrically heated ovens are

usually 208 - 240VAC, 1-phase, 3-wire (2 ‘hot’, 1 ground)

or 208-240VAC, 3-phase, 4-wire (3 ‘hot’, 1 ground),

although ovens built for export can have power require-

ments of 380VAC and 480VAC. (These ovens have a

4-wire system.) A 1.5″ (38mm) diameter cutout/hole in

the back of the machinery compartment provides ac-

cess for the electrical supply connections on 380V and

480V units. 208V and 240V 3-phase units have a cord

and plug. Using flexible cable(s) for the electrical power

supply conductors requires a 2″ (51mm) strain-relief fit-

ting (not furnished) to enable safe access to the terminal

block from which oven power is distributed.
The supply conductors must be of the size and material

(copper) recommended to provide the current required;

(refer to the data plate for the ampere specifications).

The electric current rating for each conductor supplying

a PS528-Series Oven ranges from a minimum of 16.4

amperes to a maximum of 48.1 amperes.
Typical specifications for each PS528-Series Oven are

208V or 240V, 1-phase, 3-wire, 10kW; this oven requires

60-ampere service. A PS528-Series Double Oven

(Figure 1-2) installation would require two 60-ampere

service connections, one for each oven; the 10kW power

consumption also doubles for such an installation to

20kW.
The 208V or 240VAC electrically heated oven uses two

legs of the supplied power to provide 208V or 240VAC

power for the oven control circuitry.

Figure 2-11. Junction Connection Box

Figure 2-10. Typical Electric Oven Data Plate