Control panel, Specifications, Performance data – Miller Electric Trailblazer Pro 350 D User Manual
Page 2: Engine specifications, Subject to change without notice.)

FUEL CONSUMPTION
DC POWER AMPS AT 100% DUTY CYCLE
POWER KVA AT 100% DUTY CYCLE
0
50
150
100
200
250
300
400
350
0
2
1
4
6
8
10
12
IDLE
LITERS/HR.
U.S. GAL/HR.
DC STICK
(LOW SPEED)
DC STICK/AUX POWER
(HIGH SPEED)
0.50
1.98
0.25
0.95
0
0
0.75
2.84
1.00
3.78
1.50
5.67
1.25
4.73
1.75
6.62
2.00
7.57
Welding
Mode
CC/DC
CV/DC
CC/AC
Weld Output Rated at
104˚ F (40˚ C)
300 A, 32 VDC, 100% Duty Cycle
350 A, 28 VDC, 60% Duty Cycle
200 A, 25 VAC, 60% Duty Cycle
Output
Range
20 – 350 A
10 – 34 V
35 – 250 A
Max. Open-Circuit
Voltage DC
80
50
70
CSA approved.
*Net weight with 2 gal of fuel. Add 40 lb for shipping weight.
6
2
1
3
4
11
9
10
12
7
8
5
2
Control Panel
Weight*
Net: 998 lb
(453 kg)
Dimensions
H: 30 in (762 mm)
W: 24 in (610 mm)
D: 59-1/2 in (1511 mm)
Single-Phase Generator Power
Output Rated at 104˚ F (40˚ C)
12 kVA/KW, 120/240 VAC,
100/50 A, 60 Hz
Specifications
(Subject to change without notice.)
1. Voltmeter
2. Ammeter
3. Process/Contactor Switch
4. Voltage/Amperage Adjustment Control
5. Voltage/Amperage Adjust Switch and
Remote 14 Receptacle
6. DC Polarity/AC Selector Switch
7. Fuel Gauge
8. Hour Meter
9. Engine Speed Switch
10. Glow Plug Switch
11. Engine Control Switch
12. 120/240 V Receptacles
Note: GFCIs are standard
Performance Data
FUEL CONSUMPTION DATA
• 13-gallon fuel capacity.
• Welding at 150 A at 40% duty cycle, uses only
.61 gallon per hour — over 20 hours of operation.
Engine Specifications
(Subject to change without notice.)
Engine Brand
Kubota DH905
2-year limited
North American
Manufacturer
Warranty
Horsepower (HP)
26 at 3600 RPM
Weld Speed
3600 RPM
Idle Speed
2525 RPM
Type
3-cylinder,
industrial,
liquid-cooled
diesel
Fuel
Capacity
13 gal (49 L)
Oil
Capacity
5.4 qt (5.1 L)
High Coolant Temp/
Low Oil Pressure Shutdown
Standard