41 electrical schematics – Moyer Diebel 401-HTN User Manual
Page 47

41
ELECTRICAL SCHEMATICS
BLK
BLACK
BLU
BLUE
CAM 1 HOMING
CAM 2 PUMP MOTOR
CAM 3 PUMP MOTOR REVERSING
CAM 4 DRAIN
CAM 5 FILL
CAM 6 RINSE
CAM 7 SANITIZER
CAM 8 DETERGENT
CAM 9 CYCLE
CLT
CYCLE ON LIGHT
DM
DETERGENT MOTOR
DP
DRAIN PUMP (IF USED)
RL
RELAY
DV
DRAIN VALVE
FV
FILL VALVE
GND GROUND
GRN GREEN
HTLS HIGH LIMIT THERMOSTAT
MSW MAIN SWITCH ON/FILL OFF/DRAIN
PSDR PRIME SWITCH DETERGENT, RINSE
CUSTOMER TO SUPPLY RATED
VOLTAGE/PHASE/Hz, AS SPECIFIED
PER ORDER, TO DISCONNECT SWITCH.
ALL POWER SUPPLIED TO EACH CONNECTION
POINT MUST COMPLY WITH ALL LOCAL
ELECTRICAL CODES.
00044
PSS
PRIME SWITCH SANITIZER
ICR
RELAY
DSS
REED SWITCH
RM
RINSE MOTOR (IF USED)
SRC
CURRENT OPERATED START RELAY COIL
SM
SANITIZER MOTOR
TM
TIMER MOTOR
TP
THERMAL PROTECTOR
WHT WHITE
WHTR WATER HEATER
WTS
WATER THERMOSTAT
Figure 13 — Electrical Diagram, 401-HTN