Table 6-3. Troubleshooting
TROUBLE
PROBABLE
REMEDY
Wire feeder inoperative.
Circuit breaker CB5 or CB6 open.
Reset CB5 or CB6 according to
Section 6-2.
No remote control of con-
OUTPUT/CONTACTOR switch S10
Place S10 in the REMOTE position
tactor; open-circuit voltage in the ON position.
(see Section 4-3).
present all the time when
engine is running.
No contactor control; no
CV-2 not correctly installed if done as
Review Section 3 and check all
weld output; no open-
a field kit.
connections.
circuit voltage.
Incorrect or poor connections to
Check and secure connections (see
REMOTE-5 receptacle RC3 or
Sections 3-2 and 3-3).
REMOTE-14 receptacle RC4.
Remote Contactor Control device.
Check and repair or replace remote
device as necessary.
Contactor control circuit board PC3.
Replace PC3 according to Section 6-3.
Improper current or volt-
Remote current and/or voltage control
Use only one CV-2 receptacle for
age level adjustment with
device connected at both receptacles.
remote current or voltage control.
remote control device.
No control of voltage;
CV-2 not correctly installed if done as a
Review Section 3 and check all
maximum or very low or
field kit (cables 19 and 30 from rectifier
connections, especially cables 19 and
no open-circuit voltage
SR3 reversed to Selector Switch cables). 30.
present.
Incorrect or poor connections to
Check and secure connections (see
REMOTE-5 receptacle RC3 or
Sections 3-2 and 3-3).
REMOTE-14 receptacle RC4.
CV/CC switch S12 in CC position.
Place S12 in the CV position (see
Section 4-1).
Remote Voltage Control device.
Check and repair or replace remote
device as necessary.
Voltage control circuit board PC4.
Replace PC4 according to Section 6-3.