OM-173 413 Page 25
6-3.
Connecting Optional Auxiliary Power Plant
Ref. S-188 059-A
Y
Stop engine.
Y
Power and weld outputs are
live at the same time.
Disconnect or insulate
unused cables.
.
Have qualified person install
according to circuit diagram
and Auxiliary Power Guidelines
(Section 10).
Remove junction box cover.
1
Lead 93
2
Lead 92
3
Lead 91
4
Lead 90 (Neutral)
5
Lead 42 (Circuit Grounding
Lead)
Lead 42 connects to front panel
Ground stud.
6
Grounding Terminal
7
Jumper Lead 42
8
Isolated Neutral Terminal
Jumper 42 is connected to lead 90
at factory. Jumper 42 may be dis-
connected from neutral to meet
applicable electrical codes.
9
User Supplied Leads
10 Load Terminals
Connect leads to terminals.
11 Fuses F1, F2, And F3
F1, F2, and F3 protect each load line
from overload.
.
Set Engine Control switch to
Run when using auxiliary
power.
92
90
91
93
Tools Needed:
F3
F2
F1
3
5
4
6
7
8
10
11
Volts
Amps
KVA/KW
Single
120/240
31
7.5
Three
240
24
10
60 Hz
Frequency
Engine Speed
Max. Fuse Size
35 Amperes
1850 RPM
AC
Phase
1
Phase
3
Output
Lead 42 connects to GROUND stud on front of
unit.
Jumper 42 is connected to 90 at factory.
1
2