Ap – 6 – MITSUBISHI ELECTRIC LVP-X300U User Manual
Page 33
AP – 6
How to set the grade
Use ASCII letters code to set the grade for setting data. Please refer to the table below for HEX code.
ASCII
'+'
'–'
'0'
'1'
'2'
'3'
'4'
'5'
'6'
'7'
'8'
'9'
HEX
2Bh
2Dh
30h
31h
32h
33h
34h
35h
36h
37h
38h
39h
[Example 1]
Set the AUTO POWER ON to OFF.
[Example 2]
Set the difference data of R from G to +10, the setting main data to 0 and the difference data of
B from to -5.
Sending commands
Status code from
Meaning
from the PC etc.
projector
30 30 50 2B 31 30 2B 30 30 2D 30 35 0D
Command for setting the
'0' '0' 'P' '+' '1' '0' '+' '0' '0' '-' '0' '5' '
'
picture control
30 30 50 2B 31 30 2B 30 30 2D 30 35 0D
Command received
'0' '0' 'P' '+' '1' '0' '+' '0' '0' '-' '0' '5' '
'
(Command echo back)
Sending commands
Status code from
Meaning
from the PC etc.
projector
30 30 41 50 4F 4E 30 0D
Command for setting the
'0' '0' 'A' 'P' 'O' 'N' '0' '
'
AUTO POWER ON to ON
30 30 41 50 4F 4E 30 0D
Command received
'0' '0' 'A' 'P' 'O' 'N' '0' '
'
(Command echo back)
Control this projector by using a personal computer (Continued)
The data code of CONTRAST and BRIGHTNESS is structured by the difference data of R from G, the main data and the difference
data of B from G.
[Example 3]
The TINT was set to +10 when the setting status was confirmed.
Sending commands
Status code from
Meaning
from the PC etc.
projector
30 30 53 0D
Command to confirm
'0' '0' 'S' '
'
setting of TINT
30 30 53 2B 31 30 0D
Command (setting of TINT
'0' '0' 'S' '+' '1' '0' '
'
is +10) carried out