OM-188 422 Page 17
3-7.
Remote 14 Receptacle Information
Socket*
Socket Information
24 VOLTS AC
A
24 volts ac. Protected by circuit breaker CB2.
24 VOLTS AC
B
Contact closure to A completes 24 volts ac con-
tactor control circuit.
A
J
B
K
I
115 VOLTS AC
I
115 volts ac. Protected by circuit breaker CB1.
B
C
L
N
H
D
M
G
115 VOLTS AC
J
Contact closure to I completes 115 volts ac con-
tactor control circuit.
E
F
C
Output to remote control; +10 volts dc in MIG
mode.
D
Remote control circuit common.
REMOTE
OUTPUT
CONTROL
E
0 to +10 volts dc input command signal from re-
mote control.
M
Mode select.
N
Remote inductance control.
A/V
AMPERAGE
F
Current feedback; +1 volt dc per 100 amperes.
Ref. ST-802 260
AMPERAGE
VOLTAGE
H
Voltage feedback; +1 volt dc per 10 arc volts.
G
Circuit common for 24 and 115 volts ac circuits.
GND
K
Chassis common.