2. meter functions, 3. mode switch settings – Miller Electric EXTREME 360 User Manual
Page 25

OM-229 409 Page 21
5-2. Meter Functions
.
The meters display the actual weld output values for approximately three seconds after the arc is broken.
Mode
Meter Reading At Idle
Meter Reading While Welding
Scratch
Start TIG
V
A
Actual Volts (OCV)
Preset Amps
71.7
85
Actual Volts
Actual Amps
V
A
10.3
85
Lift-Arc TIG
Actual Volts
Preset Amps
V
A
14.1
85
Actual Volts
Actual Amps
V
A
10.3
85
TIG
Blank
Preset Amps
V
A
85
Actual Volts
Actual Amps
V
A
10.3
85
MIG
Preset Volts
Blank
V
A
24.5
Actual Volts
Actual Amps
V
A
24.5
250
Pulsed
MIG
Pulse Display
Pulse Display
V
A
PPP
PPP
Actual Volts
Actual Amps
V
A
24.5
250
CC
Blank
Preset Amps
V
A
85
Actual Volts
Actual Amps
V
A
24.5
85
Stick
Actual Volts (OCV)
Preset Amps
V
A
71.7
85
Actual Volts
Actual Amps
V
A
24.5
85
V-Sense
Feeder
Flashes OCV And Preset
Blank
V
A
71.7
Actual Volts
Actual Amps
V
A
24.5
250
5-3. Mode Switch Settings
.
The Stick and CC modes provide the Adaptive Hot Start
™
feature, which automatically increases the output amperage at the start of a weld should
the start require it. This eliminates electrode sticking at arc start.
Mode Switch Setting
Process
Output On/Off Control
Mode Switch Setting
Process
Output On/Off Control
Scratch Start TIG
GTAW
Electrode Hot
Lift-Arc TIG
GTAW − See Section 5-4
Electrode Hot
TIG
GTAW With HF Unit, Pulsing Device, Or Remote Control
At Remote 14
MIG
GMAW
At Remote 14
Pulsed MIG
GMAW-P (Requires an external pulsing device.)
At Remote 14
CC
Stick (SMAW) With Remote On/Off
At Remote 14
Stick
SMAW
Electrode Hot
V-Sense Feeder
MIG (GMAW) With Voltage Sensing Wire Feeder
Electrode Hot