beautypg.com

Wiring for ac connections, Ac power distribution – Meyer Sound Mina Compact User Manual

Page 14

background image

CHAPTER 2: POWER REQUIREMENTS

14

WIRING FOR AC CONNECTIONS

MINA loudspeakers require a grounded outlet. To operate
safely and effectively, it is extremely important that the
entire system be properly grounded.

When wiring international or special-purpose power connec-
tors:

Connect the blue wire to the black terminal, or the termi-
nal marked with an N.

Connect the brown wire to the red terminal, or the termi-
nal marked with an L.

Connect the yellow and green wire to the green (or green
and yellow) terminal, or the terminal marked with an E.

CAUTION:

When creating AC power cables

and distribution systems, it is important to pre-

serve AC line polarity and connect the earth ground
on both ends of the cable. MINA requires a grounded
connection. Always use a grounded outlet and plug.
It is extremely important that the system be properly
grounded in order to operate safely and properly. Do
not ground-lift the AC cable.

AC POWER DISTRIBUTION

All components in an audio system (self-powered loud-
speakers, mixing consoles, and processors) must be prop-
erly connected to an AC power distribution system, ensuring
that AC line polarity is preserved and that all grounding
points are connected to a single node or common point
using the same cable gauge as the neutral and line cables.

NOTE:

Improper grounding of connections

between loudspeakers and the rest of the

audio system may produce noise or hum, or cause
serious damage to the input and output stages of the
system’s electronic components.

CAUTION:

Before applying AC power to any

Meyer Sound self-powered loudspeaker, make

sure that the voltage potential difference between the
neutral and earth-ground lines is less than 5 V AC.

Figure 1 illustrates a basic three-phase AC distribution sys-
tem with the loudspeaker load distributed across the three
phases. All loudspeakers are connected to common neutral
and earth-ground lines.

AC Cable Wiring Scheme

Blue = neutral

Brown = hot

Yellow/green =
earth ground
(chassis

!

Figure 1: AC Power Distribution System

!

Line 1

Line 2

Line 3

Neutral

Earth Ground