STARTING/STOPPING INSTRUCTIONS

On/Off Stop Control

Throttle Control

Idle

Fast

STARTING INSTRUCTIONS

Fig. 10

Fig. 11

STOPPING INSTRUCTIONS

1. Move the throttle control to the idle position (

). Allow the

engine to cool down by idling.

2. Put the On/Off Stop Control in the OFF (O) position.

NOTE: There is no need to turn the unit on. The On/Off

Stop Control is in the ON (I) position at all times.

2. Fully press and release the primer bulb 10 times,

slowly. Some amount of fuel should be visible in the
primer bulb
and fuel lines (Fig. 11). If you can’t see
fuel in the bulb, press and release the bulb as many
times as it takes before you can see fuel in it.

3. Place the unit in the starting position (Fig. 12 as a

blower, Fig. 13 as a vacuum). Move the throttle control
to the idle position
(

) (Fig. 10). This is especially

important during cold starting.

4. Push the blue EZ-Start™ Lever towards the primer

bulb until it clicks and locks into place (Fig. 11).

5. Pull the starter rope out with a controlled and steady

motion until the engine attempts to start. Repeat until
the engine starts.

NOTE: The unit uses Spring Assist Starting™, which

significantly reduces the effort required to start the
engine. You must pull the starter rope out far enough
to hear the engine attempt to start. There is no need
to pull the rope briskly-- there is no harsh resistance
when pulling. Be aware that this starting method is
vastly different from (and much easier than) what you
may be used to.

6. When the engine starts, move the throttle control to the

fast position (

) and let the engine warm up for 15 to

30 seconds. The blue EZ-Start™ Lever will click off
automatically
when you move the throttle control to
the fast position.

IF...

The engine does not start, go back to step 2.

NOTE: If you are having trouble starting the unit or are

operating in extreme temperatures (below 40º F,
above 90º F), refer to the Troubleshooting section.

Vacuum
Starting

Position

Starter

Rope

Starter

Rope

Blower

Starting

Position

Fig. 12

Fig. 13

Operate this unit only in a
well- ventilated outdoor

area. Carbon monoxide exhaust fumes can be
lethal in a confined area.

WARNING:

Avoid accidental starting.

Make sure you are in the

starting position when pulling the starter rope (Fig.

12 and 13). To avoid serious injury, the operator and

unit must be in a stable position while starting.
Do not set unit on any surface except a clean, hard

area while starting. Debris such as gravel, sand,

dust and grass could be picked up by the air

intake and thrown out by the discharge opening.

This could damage the unit, property, or cause

serious injury to bystanders or the operator.

WARNING:

To avoid serious

personal injury,

always remove the vacuum bag prior to

refueling the unit. The bag may become a

fire hazard when saturated with fuel.

WARNING:

Primer

Bulb

Blue EZ-Start™

Lever

1. Mix gas with oil. Fill fuel tank with fuel/oil mixture.

See Oil and Fuel Mixing Instructions.