Troubleshooting Guide (continued)
SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
The unit powers
Beeper disabled. No tone
Enable beeper. Select tone
up, but does not
selected
scan and/or beep
The unit powers
Scanning a particular
UPC/EAN, Code 39, interleaved 2 of
up, but does not
symbology that is not
5, Code 93, Code 128 and Codabar
scan and/or beep
enabled
are enabled by default. Verify that the
type of bar code being read has been
selected
The unit powers
The scanner has been
Verify that the bar code that is being
up, but does not
programmed for a
scanned falls into the criteria. (Typical
scan and/or beep
character length lock, or a
minimum length and bar
code being scanned does
not satisfy the programmed
criteria
of Non-UPC/EAN codes.) (The
scanner defaults to a minimum of 4
character bar code)
The unit scans a
The scanner is configured
If the scanner is setup to support
bar code, but
to support some form of
ACK/NAK, RTS/CTS, XON/XOFF or
locks up after the
host handshaking but is not
D/E, verify that the host cable and host
first scan (red
receiving the signal
are supporting the handshaking
LED stays on)
properly
The unit scans,
The scanner’s data format
Verify that the scanner’s data format
but the data
does not match the host
matches that required by the host.
transmitted to
system requirements
Make sure that the scanner is
the host is
connected to the proper host port
incorrect