Installation – Garland E24-72G User Manual
Page 7
Part # 1009080 Rev 5 (01/25/08)
Page 7
INSTALLATION
Unpacking
Unpack units carefully and provide the necessary space on
counter of back bar . All units must be installed following the
minimum back and side clearances stated on the tag affixed
to each individual unit . To insure proper field wiring size
check tag attached to the rear of the unit near knockout .
Leg Installation
1 . All units are shipped with N .S .F . approved legs . These
legs must be installed to provide a minimum clearance
of 4” (102mm) between he counter top and bottom of
the appliance in order to meet the National Sanitation
Foundation requirements .
2 . When using the legs described above, raise the front of
the appliance and screw the leg into the leg-retaining nut
provided at each corner of the appliance, repeat at each
rear .
. The unit may be leveled by adjusting the legs . Use a spirit
level and level the appliance four (4) ways: across the
front and back; and down left and right edges .
NOTE: Griddles may not rest evenly on the appliance body if
the appliances are not leveled .
Electrical Connections
Before attempting the electrical connection, the rating
plate should be checked to ensure that the unit’s electrical
characteristics and the supply characteristics agree .
Installation of the wiring must be made in accordance with
UL 197 Commercial Electric Cooking Appliance Standards,
Local and/or National Electrical Code, and ANSI/NFPA 70-
1990 and include .
1 . Switch panel size
2 . Overload protection
. Wire type
4 . Wire size
5 . Temperature limitations of the wires
6 . Method of connection (Cable, Conduit, etc .)
The service line enters though the rear of the unit and is
to be connected to the terminal block . Input voltage and
phasing must match the unit’s voltage and phasing .
Visually check all electrical connections .
Energize the electrical connections .
NOTE: Appliances are not internally fused . They must be
connected to a suitable disconnect box in accordance with
local code .
E24-12H Hot Plate
Electrical connection to the terminal may be made though
the knockout on the main back . Front access is gained by
raising the rear surface element and removing bowl . The
terminal block shield is located toward the back lower left of
the unit .
E24 Series Griddles
The electrical connections may be made though the
knockout at the rear of the unit to the terminal block located
behind the terminal block shield .
Front access is gained by raising and propping the griddle
plate . The terminal block shield is toward the back and left
of the appliance . Remove the shield to expose the terminal
block . Make the necessary connection and replace the shield .
These appliances have no fusing .