Slow Flash
N/A
Normal operation.
Standby Mode.
●
No problem.
Fast Flash
N/A
Normal operation.
Heat Mode.
●
No problem.
1 Flash
1 Flash
Lockout condition.
Ignition Failure.
●
Third failed ignition attempt. Unplug to reset
control. Contact qualified service technician.
●
Make sure manual gas shutoff valve is open.
●
If pressure is too high, the valve will not
operate.
l
●
Clean any scale buildup from burner and pilot
assembly. (Refer to page 26)
●
The spark ignitor assembly could be damaged
or broken. If so, replace assembly.
●
Bleed air from gas line. (Refer to page 28)
2 Flashes
1 Flash
Lockout condition.
Flammable Vapors Present.
●
Contact local qualified service technician.
2 Flashes
3 Flashes
Lockout condition.
FVD Interface Failure/Miswiring
(Flammable Vapor Sensor Failure).
●
Contact local qualified service technician.
3 Flashes
1 Flash
Lockout condition.
Pressure Switch Fails to Open.
●
Contact local qualified service technician.
3 Flashes
3 Flash
Lockout condition.
Pressure Switch Fails to Close.
●
Contact local qualified service agent.
Inspect vent pipe and dilution air inlet for
blockage. (Refer to “Routine Preventive
Maintenance” Section.)
4 Flashes
1 Flash
Lockout condition.
Line/Neutral Polarity Failure.
●
Check the electrical supply outlet.
4 Flashes
2 Flash
Lockout condition.
ECO Failure.
●
Contact local qualified service technician.
4 Flashes
3 Flash
Lockout condition.
False Flame (Unwanted Flame
Present).
●
Unplug to restart control. Contact local
qualified service technician.
5 Flashes
-
Vacation Mode Active
●
Select desired temperature setting.
LED Steady ON
N/A
Lockout condition.
System Error, Cycle Power.
●
Contact local qualified service technician.
30
Gas Valve LED Error Codes
CAUTION: For your safety DO NOT attempt repair of gas piping, remote control, burners, vent connectors or other safety
devices. Refer repairs to qualified service personnel.
CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation. VERIFY PROPER OPERATION AFTER SERVICING.
Customer Service
T
roubleshooting Tips
Care and Cleaning
Operating Instructions
Installation Instructions
Safety Instructions