3.13 SERVICE SCHEDULE

ATTENTION: It is recommended that all service work

be performed by the nearest Generac Authorized Service Dealer.

SYSTEM/COMPONENT

PROCEDURE

FREQUENCY

X = Action

Inspect

Change

Clean

D = Daily

W = Weekly

R = Replace/Adjust as Needed

M = Monthly

Y = Yearly

* = To Be Completed by a

H = Hours

Generac Authorized
Service Dealer.

FUEL
Fuel level

X

AFTER 25-H BREAK-IN,

D / BEFORE USE

Fuel lines and connections*

X

AFTER 25-H BREAK-IN,

EVERY 250 H / 6 M

Fuel Filter*

X

EVERY 250 H / 6 M

LUBRICATION

Oil level

X

EVERY 8 H / D

Oil

X

AFTER 25-H BREAK-IN,

EVERY 250 H / 6 M

Oil Filter

X

AFTER 25-H BREAK-IN,

EVERY 250 H / 6 M

Oil line leakage*

X

EVERY 100 H

COOLING
Engine cooling system*

X

AFTER 25-H BREAK-IN,

EVERY 100 H / M

Coolant level

X

AFTER 25-H BREAK-IN,

D / BEFORE USE

Coolant*

X

EVERY 500 H / Y

Enclosure louvers

X

X

EVERY 250 H / 6 M

EXHAUST
Exhaust system

X

EVERY 100 H / M

Retorque Exhaust Manifold*

X

EVERY 750 H

Clean out Muffler/Spark Arrestor

X

EVERY 150 H/Y

BATTERY

Electrolyte fluid level

X

AFTER 25-H BREAK-IN, W

Charge and condition

X

R

X

W, EVERY 250 H / 6 M

FAN/ALTERNATOR BELTS
Tension and condition*

X

R

EVERY 750 H

ENGINE
Retorque cylinder head*

X

EVERY 750 H

Retorque intake manifold*

X

EVERY 750 H

Starter motor*

X

EVERY 750 H

Air filter

X

R

EVERY 500 H

Compression*

X

EVERY 750 H

Valve clearance*

X

R

EVERY 750 H

Governor*

X

R

EVERY 750 H

Safety devices*

X

R

EVERY 750 H

Injection system*

X

R

EVERY 750 H

GENERAL
Overall condition

X

X

AFTER 25-H BREAK-IN, W

Exercise system

W

COMPLETE TUNE-UP*

X

X

X

Y

16 Generac

®

Power Systems, Inc.

Section 3 – Maintenance

QUIETPACT™ 75D Recreational Vehicle Generator