Lamp Specification—
The Ultra
★
★
★
★
★Sport floodlight
takes advantage of metal halide lamp technology,
proven by decades of use in all types of lighting
application. It uses an advanced generation of lamps
specifically designed for use in sports lighting.
Offered in a choice of 2000, 1500 or 1000 watts, these
white light sources feature a double-ended design
without an outer bulb, and provide an average rated
life of 3000, 6000 and 10,000 hours, respectively.
These advanced lamps also provide excellent color
rendering with a 4000 degree Kelvin color
temperature. They are designed for an orientation of
horizontal plus or minus 4 degrees, and have no tilt
factor.
Lamp Installation—
Ultra
★
★
★
★
★Sport floodlights are
shipped with lamps installed.
The double-ended metal halide lamp mounts
transversely to a specific orientation by inserting the
lamp ends into pre-focussed ceramic holders. It is
held in place by stainless steel spring clips that snap/
lock in place. The electrical connection of the lamp is
separate from the mechanical support, and is made by
connecting the spade ended-lamp leads to the socket
terminals and tightening with a screwdriver.
8
GE is . . . Sports Lighting!
e
Metal Halide
Metal Halide
2000 Watt Double-Ended
1500 Watt Double-Ended
GE Lamp Number
MQI/2000/T9/40
MQI/1500/T8/40
Catalog Number—OSRAM Sylvania
M2000T9/DE
M1500/T9/DE
ANSI Designation
U134
U133
Burning Position
Horizontal ± 4 Degrees
Horizontal ± 4 Degrees
MOL
10.00 Inches (254mm)
10.00 Inches (254mm)
LCL
5.00 Inches (127mm)
5.00 Inches (127mm)
Arc Length
4.25 Inches (108mm)
4.25 Inches (108mm)
Base
Ceramic #10 Spade
Ceramic #8-10 Spade
Lamp Volts
250 ± 10 Volts
265 ± 10 Volts
Lamp Current
8.5 Amps
6.3 Amps
Ignitor Pulse (Peak)
4000-5000 Volts
4000-5000 Volts
Pulse Width @ 3600 volts
One Microsecond
One Microsecond
Minimum Pulse Required
4000 Volts
4000 Volts
Initial Lumens
200,000
160,000
Lumens at 100 Hours
100%
100%
Lumens at 40% Rated Life
85%
85%
Average Rated Life
3000 Hours
6000 Hours
Color Temperature
4000° Kelvin
4000° Kelvin
CRI
RA=65+
RA=65+
Hot Restart Capability
Yes
Yes
Lamp Seal Temperature
Not to exceed 450 degrees C.
Not to exceed 450 degrees C.
Bulb Wall Temperature
Not to exceed 950 degrees C.
Not to exceed 950 degrees C.
LAMP DATA