Setting tone controls, Vertical / horizontal mounting, Console top mounting – Genelec 1030A User Manual
Page 3: Maintenance, Safety considerations, Accessories, Guarantee

gives an SPL of 100 dB @1m with -6 dBu 
input level. 
Setting tone controls
The response of the system may also have 
to be adjusted to match the acoustic envi-
ronment. The adjustment is done by setting 
the three tone control switch groups ‘treble 
tilt’, ‘bass tilt’ and ‘bass roll-off’ on the rear 
panel of the amplifier. The factory settings 
for these controls are ‘All Off’ to give a flat 
anechoic response. See Table 1 for sug-
gested tone control settings. Figure 5 shows 
the effect of the controls on the anechoic 
response. Always start adjustment by setting 
all switches to ‘OFF’ position. Then set only 
one switch to the ’ON’ position to select the 
response curve needed. If more than one 
switch is set to ‘ON’ (within one switch group) 
the attenuation value is not accurate.
Vertical / horizontal mounting
The speakers are normally delivered set 
up for vertical mounting. Horizontal mount-
ing should be avoided due to the increased 
likelihood of early reflections that degrade 
the the direct sound. If horizontal mounting 
is needed the DCW plate may be rotated so 
that the Genelec logo remains horizontal by 
removing the four corner screws of the DCW 
and carefully lifting and turning the DCW.
Console top mounting
If the 1030A’s are used for near field monitor-
ing, avoid mounting them on the meter bridge 
of the console. Instead position the speakers 
slightly behind the console by using floor 
stands or wall mounts. This prevents the 
first reflections from the console surface from 
coloring the sound.
Maintenance
No user serviceable parts are to be found 
within the amplifier unit. Any maintenance 
or repair of the 1030A unit should only be 
undertaken by qualified service personnel. 
Safety considerations
Although the 1030A has been designed 
in accordance with international safety 
standards, to ensure safe operation and to 
maintain the instrument under safe operating 
conditions, the following warnings and cau-
tions must be observed:
1. Servicing and adjustment must only
be performed by qualified service 
personnel. The amplifier’s rear panel must
not be opened.
2. Do not use this product with an
unearthed mains cable as this may lead to
personal injury.
3. To prevent fire or electric shock, do not
expose the unit to water or moisture. Do
not place any objects filled with liquid,
such as vases on the speaker or near it. 
4. Note that the amplifier is not
completely disconnected from the AC 
mains service unless the mains power
cord is removed from the amplifier or the
mains outlet.
WARNING! 
This equipment is capable of producing 
sound pressure levels in excess of 85 dB, 
which may cause permanent hearing 
damage.
Accessories
Order code
Protective grille
1030-409
Wall mount
1030-404-V/H*
Floor stand
1030-405-V/H*
*State the desired speaker orientation 
V=vertical or H=horizontal when ordering 
these accessories.
Guarantee
This product is supplied with one year guar-
antee against manufacturing faults or defects 
that might alter the performance of the 1030A 
unit. Refer to supplier for full sales and guar-
antee terms.
Figure 1. Amplifier panel layout of the 1030A
Figure 2. Location of the acoustic axis
Speaker Mounting
Position
Treble tilt
Bass tilt
Bass roll-off
Flat anechoic response
None
None
None
Free standing in a
damped room
None
-2 dB
None
Free standing in a
reverberant room
None
-4 dB
-2 dB
Near field or console
bridge
None
-4 dB
-4 dB
Table 1. Suggested tone control settings in some typical situations
Figure 3. RCA to XLR cable