User instructions, General, Recommended fuels – Stovax Stockton 7 7125F User Manual
Page 2: Lighting the appliance

2
1. GeNeRAL
1.1 These instructions apply to Stockton 3/4/5/6/7 when fitted
with a Smoke Control kit.
NOTE: These appliances have been independently tested to
PD6434 and approved by DEFRA as an exempted appliance
allowing it to burn wood in Smoke Control areas when fitted
with a Smoke Control kit.
Product
code
Appliance
smoke control kit
Part No.
7125
Stockton Inset Convector
ST5SCKIT
1.2 To meet the Smoke Control requirement this appliance must
be operated correctly in order to minimise the amount of
smoke produced.
1.3 Burn only dry wood
1.4 These instructions must be left with the user and kept with
the original instructions they superseded.
2. RecOMMeNDeD FueLs
2.1 wood Logs:
• Burn only seasoned timber with a moisture content of less
than 20%
Appliance
Maximum Length
Maximum Diameter
Stockton Inset
Convector
325mm
100mm
• Dry cut wood for 12 to 18 months before use
Poor quality timber:
— Causes low combustion efficiency
— Produces harmful condensation
— Reduces effectiveness of the airwash and life of the
appliance
Do not burn construction timber, painted, impregnated /
treated wood, manufactured board products or pallet
wood
.
3. LIGhTING The APPLIANce
3.1 For best results:
• Set air controls, See below.
Air Wash: Fully Open
Primary Air: 25% Open
Stockton 7
Stockton 8
Stockton 7
Stockton 8
Secondary Air:
Fully Open
• Place firelighters or paper and dry kindling wood on the
grate
• Light the paper or firelighters, See Diagram 2
• Leave the door slightly open as the fire establishes and
the glass warms to avoid the build-up of condensation
• Add larger pieces of wood
Too many logs may smother the fire.
Do not load fuel above the log guard and the secondary
combustion inlets at the back of the firebox.
See Diagram 3
useR INsTRucTIONs