Installation

310554V

13

Installation

Grounding the Control Assembly

Connect a ground wire from the GND terminal in the
PrecisionSwirl control assembly (shown in F

IG

. 5) to a

true earth ground.

FIRE, EXPLOSION, AND ELECTRIC SHOCK

HAZARD

To reduce the risk of fire, explosion, or electric shock:

The PrecisionSwirl control assembly must be elec-
trically connected to a true earth ground; the
ground in the electrical system may not be suffi-
cient.

All wires used for grounding must be 8 AWG (8.36

mm

2

) minimum.

A qualified electrician must complete all grounding
and wiring connections.

Refer to your local code for the requirements for a
“true earth ground” in your area.

Also read and follow the warnings on page 4.

CAUTION

If power and grounding connections are not done
properly, the equipment may be damaged and the
warranty will be voided.

CAUTION

To help avoid damage to equipment, make sure that
the robot and PrecisionSwirl equipment are grounded
to the same point.

F

IG

. 5

,

'.$

#2

#2

#2

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

'.$

'.$

'.$

'.$

'.$

L1

L2/N

PE/GND

Power Terminals

NOTE: PE is the international designation for
the primary earth ground terminal. GND may
be used elsewhere on Graco equipment.