-52-
G0605X/G0606X Extreme Series 12" Table Saw
Figure 82. Shim procedure diagram A.
Figure 83. Shim procedure diagram B.
8. Tilt the blade to 45° and repeat Steps 2-6. If
the blade is still parallel to the miter slot, con-
tinue on to the 
Blade Alignment procedure.
Otherwise, continue with the next step.
9. If the blade was parallel to the miter slot at
90° but not at 45°, the table will need to be 
shimmed with metal shim stock. The shims 
are placed under the table over each of the 
three table mounting bolts.
10. Refer to Figures 82 and 83 for shim place-
ment. If the distance of A is shorter than B, 
shim(s) will need to be placed under corners 
#1 and #2. If the distance of B is shorter than 
A, shim(s) will need to be placed under cor-
ner #3. Very thin shim stock works well.
11. Tighten down one bolt a small amount and
then move on to each of the others, tighten-
ing each down the same amount. Continue 
to rotate through the bolts, tightening them a 
little each time until they are all secure.
12. Now recheck the blade to miter slot at 90°
and 45° by repeating
Steps 2-6. If the dis-
tance of A and B are equal, continue to the
Blade Alignment procedure. If the distances 
are still off, repeat 
Steps 10-13.
13. Once you feel you have the miter slot adjust-
ed to the blade, recheck all measurements 
and be sure the table mounting bolts are 
secure. Also, if you ever remove the table 
in the future, be sure to make note of shim 
placements and reassemble exactly how it 
came apart.