8.1

Turn the gas supply off at the isolation device. Locate the

main injector on the LH side of the airbox, undo the

compression nut and pull the pipe clear of the injector

body, see diagram 13A.

8.2

Rotate the injector until it is fully removed, and install the

correct replacement injector. Reassemble and turn the gas

supply on, check for leaks.

.

If the stove has been installed in a restrictive location, it

may be necessary to remove the stove from its location.

9.1

Locate the sensor in the draught diverter opening, and

gently pull the two wires off the terminals. Undo the two

taptite screws and remove the sensor and the two plastic

spacers. See diagram 14.

9.2

Refit a new sensor ensuring the spacers are located between

the sensor and the bracket. Replace the two leads.

9.3

If it has been necessary to remove the stove, ensure that all

disturbed gas joints are checked for gas soundness when

reinstalled, and repeat the flue clearance test as detailed in

the Commissioning Section.

10.1 Turn the gas supply off at the isolation device.
10.2 Locate the aeration plate on the underside of the airbox

and remove the Nyloc nut, see diagram 15.

10.3 Remove the plate and replace with the correct size, ensure

that the hole(s) in the plate align correctly with the holes in

the underside of the airbox and replace the Nyloc nut.

11.1 In order to change between gas types, it will be necessary

to change the following items.
• Pilot Unit
• Control Valve
• Main Injector
• Aeration Plate (if required)
• Databadge
The relevant parts can be ordered as a conventional kit

from Gazco. Always quote the appliance type and serial

number when ordering spare parts.
** NOTE: THE CONTROL VALVE IS FACTORY PRESET

FOR CORRECT GAS TYPE AND MODEL. A NEW UNIT

WILL NEED TO BE ORDERED WHEN CHANGING

BETWEEN GAS TYPES.

SERVICING INSTRUCTIONS

REPLACING PARTS

8. MAIN INJECTOR

13

14

15

9. GAZCO FLUE SURE SYSTEM

10. PRIMARY AERATION PLATE

11. CHANGING BETWEEN GAS TYPES

AR0389

AR0381

A

AR0380