beautypg.com

Global Machinery Company FCG001 User Manual

Page 16

background image

16

Troubleshooting

Trouble

Possible cause

Suggested remedy

Engine will not start or will

not keep running

1. Low on fuel/oil content

1. Add fuel/oil mix

2. Ignition switch in “Off” position

2. Turn to “ON” position

3. Faulty spark plug

3. Replace spark plug

4. Choke in wrong position

4. Adjust choke accordingly

5. Fuel tap in closed position

5. Open fuel tap

6. Unit loaded during start-up

6. Remove load from unit

7. Spark plug wire loose

7. Attach wire to spark plug

8. Dirty fuel filters

8. Clean filters as per instructions

No electrical output

1. Faulty receptacle

1. Have service centre replace receptacle

2. Circuit breaker kicked out

2. Depress and reset

3. Defective capacitor

3. Have service centre replace capacitor

4. Faulty power cord

4. Replace cord

Repeated circuit breaker

tripping

1. Overload

1. Reduce load.

2. Faulty cords or equipment.

2. Check for damaged, bare, or frayed wires

on equipment. Replace.

Generator overheating

1. Generator overloaded.

1. Reduce load

2. Insufficient ventilation.

2. Move to adequate supply of fresh air.