PROBLEM

POSSIBLE CAUSE

WHAT TO DO

Burner backfiring
during operation

Extremely sooty flame.

Slight smoke and odor
during initial operation

Heater produces a
whistling noise when
burner is lit.

Heater produces a
clicking noise just
after burner is lit or
turned off.

Gas odor even when
control knob is in OFF
position.

Gas odor during
combustion

Heater shuts off
on ODS

1. Burner orifice is clogged.
2. Burner ports damaged.

1. Lack of primary air.

2. Flame impingement on log.

3. Incorrect orifice size.

1. Residues from

manufacturing processes.

1. Air passageways blocked.

2. Air in gas line

1. Metal expanding and

contracting, respectively.

1. Gas leaks. See front page

Warnings.

2. Gas control defective

1. Foreign matter in gas or on

burner ports.

2. Heater burning vapors from

paint, impurities in air.

3. Gas leaks. See front page

Warnings.

1. Not enough fresh air is

available.

2. Low gas pressure

3. ODS pilot partially clogged.

1. Clean burner orifice.
2. Replace burner.

1. Check primary air

opening for blockage.

2. Check & correct log

position.

3. Install correct orifice

size for right type of gas
& elevation.

1. Will stop after a few

hours of operation.

1. Check minimum

installation clearances
and air passageways for
debris.

2. Operate burner until the

air is completely purged.

1. This is common with

heaters. If noise is
excessive, contact a
qualified person.

1. Locate and correct leaks

immediately.

2. Replace gas control

1. Check gas passage way

and burner.

2. Ventilate room, stop

storing and using odor
causing products near
the heater.

3. Locate and correct

leaks immediately.

1. Open window.

2. Contact your gas

company.

3. Clean the pilot.