beautypg.com

Troubleshooting – Global Machinery Company G25 User Manual

Page 18

background image

18

Troubleshooting

Trouble

Possible cause

Suggested remedy

Engine will

not start

1. Low on fuel or oil content

1. Add fuel or oil

2. Ignition switch

in “Off” position

2. Turn to “ON” position

3. Faulty spark plug

3. Replace spark plug

4. Choke in wrong position

4. Adjust choke accordingly

5. Unit loaded

during start-up

5. Remove load from unit

6. Spark plug lead

loose/disconnected

6. Disconnect the spark plug lead and reattach spark plug lead.

7. Unit may be flooded

7. Leave the generator rest for 5-10 minutes and then try again,

following the instructions when doing so. Alternatively if the

choke lever is in full choke position (start), switch the choke to

the run position and try to re-start.

8. Old Fuel

8. Remove the existing fuel and replace with new.

AC power supply

- No electrical

output

1. Faulty receptacle

1. Have service centre replace receptacle

2. Is the green LED on

with motor running

and no output?

2. YES - Try another appliance that is known to work.

Reduce the load if required.

NO - Organise for the unit to be serviced.

3. Check to make sure

the red overload LED

is not on?

3. If it is - reduce the load.

4. Faulty power cord

4. Replace cord

DC power supply

- No electrical

output

1. Circuit breaker kicked

out (DC only)

1. Yes – Depress the reset button, to rest the circuit breaker