beautypg.com

Warning, electric shock hazard, Complete the hook up – Grindmaster 67710E User Manual

Page 7

background image

Page 7

American Metal Ware 67710E Coffee Urn

Installation

Initial Considerations

Unpack the Urn

Remove the cardboard carton from around the urn. Be careful not to scratch the stainless

steel with any tools. Unwrap any plastic wrapped items. Open both liner covers and

remove materials inside the liners. Remove the control enclosure to expose electric

connections.

Select a sight for the urn

The Urn must be placed on a sturdy, leveled table. The table must have a tray to collect

liquid from the faucets. To set up initially and adjust later, the installer must have access to

the side of the urn where the controls are located. Be sure to allow for space in the sight

selection.

Water and Electric

The electric ratings are printed on the nameplate of the urn and on the rough-in drawing.

The urn must be connected to a branch circuit with its own shut-off.

A water line must be run to the connection location. The urn has a 3/8” NPT water inlet as

shown on the rough-in drawing. Use 3/8” OD copper tubing for the connection. For

especially long runs where pressure drop is likely to be a problem, use larger tubing. The

water line should have a shut-off valve near the urn. The water pressure at the urn should

be between 30 and 70 psig.

Softened water does not make good coffee. For best results, use cold tap water. Cold

water will require a recovery time between brews. You may connect hot water if it is

necessary to brew in both liners continuously. Chlorine and lime in water are the biggest

problems in the operation of coffee brewers. Be sure the water is free of chlorine which will

deteriorate the stainless steel. Filters may be purchased to help control lime. American

Metal Ware’s warranty does not cover water problems.

Place Urn

Position the urn on the table in its operating position. Level the urn front to back and left to

right. The height of the feet is adjustable for this purpose.

Complete the Hook Up

Water Hook-Up

The water connection is on the back of the urn’s control enclosure - see figure 1.

WARNING, ELECTRIC SHOCK HAZARD

INSTALLATION SHOULD BE PERFORMED BY QUALIFIED
SERVICE PERSONNEL ONLY.

!