beautypg.com

Iagrama, Ableado, Specificaciones – Goodman Mfg 13 SEER GPC13H User Manual

Page 16: Roducto

background image

E

SPECIFICACIONES

DEL

P

RODUCTO

16 www.goodmanmfg.com

SS-GPC13H-SP

D

IAGRAMA

DE

C

ABLEADO

: GPC1324-48H41**

NOTE #4

FC

NOTE#2

EM

M1

COM

TR

24V

208-240

NO

EBTDR

N

C

3

240

208-240/1/60

SUPPLY VOLTAGE

C

COMP

C

S.A.

S

T1

R

FC

L1

BR

C

NOTE #5

H

F

RCCF

CM

T2

CH

C

L2

PU

BK

RD

RD

BK

H

RCCF

F

C

YL

BR

K1

K1

M1

NOTE #2

XFMR-C

PU

SPEED

C

BL

XFMR-R

R

G

EBTDR

GR

COM

NC

NO

RD

2

24V

BL

208

TR

C

BK

1

PU

COMP

CM

RD

RD

NOTE #3

CH

BR

BR

PU

4

1

PLF

BK

YL

S

BK

RD

BK

5

6

2

3

C R

RD

BL

BR

WH

GR

YL

R

C

W2

W1

G

Y

A
T

O

T

S

M

R

E

H

T

T2

T1

RD

BL

NOTE #4

PU

BL

L1

YL

GND

C

L2

PU

60

/

/

1

0

4

2

-

8

0

2

HIGH

(COM)

BK

(TRANS240V)

PU

(M1) RD

BR

FC

LOW

OPTIONAL

2 SPEED

BR

EM

3 SPEED

EM

M2

M2

7

8

9

BL

BR

BK

208-240/1/60 0140G00892 REV. A

RD

RD

RD

RD

BK

BK

BK

BK

RD

BK

BK

RD

COMPONENT
LEGEND

BR
C
CH
CM
COMP
EBTD
R
EM
FC
GND
LVJB
PLF
RCCF

SA
TR

HPS

BLOWER INTERLOCK RELAY
CONTACTOR
CRACKCASE HEATER
CONDENSER MOTOR
COMPRESSOR
ELECTRONIC BLOWER TIME DELAY
RELAY
EVAPORATOR MOTOR
FAN CAPACITOR
EQUIPMENT GROUND
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER

HIGH PRESSURE SWITCH

WIRE CODE

BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW

FACTORY WIRING

LINE VOLTAGE
LOW VOLTAGE
OPTINAL HIGH
VOLTAGE

FIELD WIRING

HIGH VOLTAGE
LOW VOLTAGE

+
+

EBTDR

R

G

C

R

W2

W1

Y

G

C

4

5

6

EBTDR

P
L
F

1

3

2

LVJB

SA
(IF USED)
SEE NOTE 5

THERMOSTAT

SEE NOTE #3

PU

PU

YL

RD

BL

BL

4

2

3

1

RD

RD

PU

PU

UP

BR

1

3

3

1

BR

2

4

SEE NOTE #6

BK

RD

SEE UNIT RATING PLATE FOR TYPE AND SIZE

OF OVER CURRENT PROTECTION

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT
LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR
"COM" WITH LEAD
ON EBTDR "M1" OR "M2"
3. CRANKCASE HEAT NOT SUPPLIED ON ALL UNITS.
4. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
FROM TERMINAL 3
TERMINAL 2 ON TRANSFORMER.
5. START ASSIST FACTORY EQUIPED WHEN REQUIRED
6. USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE

P
L
F

CONTROL
BOX

HPS

C

HPS

PU

El cableado está sujet

o a cambios

. Siempr

e c

onsult

e el diag

rama de cableado de la unidad para obt

ener la inf

ormación más ac

tual

izada.

ADVERTENCIA

Alt

o

v

oltaje:

Desc

onec

te

t

odas las fuent

es de ener

gía ant

es

de instalar o hac

er mant

enimient

o

de la unidad

. Es posible

que ha

ya

v

arias fuent

es de ener

gía. En caso c

o

ntr

ario

, puede causar daños ma

teriales

, lesiones o la muer

te

.