Important: in locations where a sump pump failure, flooding or
exposure to water may be present, a ground fault receptacle is
recommended.

VI)

Lighting and Operating Instructions

WARNING

READ BEFORE PROCEEDING

If you do not understand and follow these
instructions, a fire or explosion may result.

This

Superflue

Water Heater is equipped with an electric

combination thermostat / gas valve control and an ignition device
that lights the burner.

DO NOT ATTEMPT TO LIGHT

THIS WATER HEATER MANUALLY!

The control

contains internal self-diagnostic features and an external LED
monitor light (Figure 11).

During operation a flashing LED indicates a burner or ignitor
failure, putting the system into a safety lockout condition. This
control uses three attempts at ignition before locking out. To
reset a system in lockout, disconnect electrical power, wait ten
seconds and re-energize. If the system fails to re-start, see
trouble shooting section.

A “constant on” LED indicates an unserviceable fault within the
control, and cannot be reset. The complete control must be
replaced.