SERVICING INSTRUCTIONS
REPLACING PARTS
In order to change between gas types it will be necessary to
change the following items.
Main Injector
Main Burner
Pilot Injector
Control Valve
Control Box
Thermocouple ( NG to LPG only).
LPG to NG no change).
Data Badge
NOTE: THIS ONLY NEEDS TO BE DONE IF ACCESS IS
TO THE CONTROLS IS RESTRICTED.
14.1 Remove the outer decorative front, refer to the instructions
supplied with the front.
14.2 Remove the lower cover. See diagram 6.
14.3 Disconnect the gas pipe at the isolation device. See diagram
21 arrow B.
14.4 Remove the glass frame. See diagram 22 arrow C.
13. CHANGING BETWEEN GAS TYPES
14. CONTROL BRACKET ASSEMBLY
21
AR1344
14.5 Remove the main burner as described in section 2.
14.6 Remove the injector locknut. See diagram 23.
14.7 Disconnect the touch pad from the harness. See diagram 21
arrow A.
14.8 Disconnect the ignition lead from the electrode.
14.9 Remove the thermocouple. See diagram 21 arrow C.
14.10 Remove the pilot pipe and ensure the pilot injector is kept
safe.
14.11 Remove the two screws securing the control bracket from
under the appliance. See diagram 21 arrow E.
14.12 Tilt the front edge of the bracket down slightly and move
the assembly to the right to disengage the injector. Rotate
the left hand side forward and down to allow the removal
of the injector from the side of the appliance. The assembly
should now be free of the appliance.
14.13 Reassemble in reverse order and check for gas leaks.
22
AR1338
23
AR1345
B
A
E
E
C
C
C
C
C
C
C
C
C
C