8

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATION

COVERING THE FOLLOWING MODELS:

MARLBOROUGH – 8535LUC – P8535LUC

STOCKTON – 8570LUC – P8570LUC

Model

Gas

Gas

Working

Aeration

Injector

Gas Rate

Input kW (Gross)

Country

CAT.

Type

Pressure

m

3

/h

High

Low

8535LUC

I

2H

Natural

20 mbar

Ø 1 x 14.5

375

0.600

6.4

3.6

GB, IE

8570LUC

(G20)

P8535LUC

I

3P

Propane

37 mbar

Ø 2 x 12

165

0.221

6.15

3.6

GB, IE

P8570LUC

(G31)

Rear Exit Flue

Wall Thickness:

Min

Max

200mm 550mm

Efficiency Class I

Flue Outlet Size 100 Ø / 152mm

Gas Inlet Connection Size 8mm Ø

RESTRICTOR REQUIREMENT

Vertical & Horizontal Flue Specification

Vertical Flue Height from Top of Appliance

Horizontal Length

Restrictor Size

500mm up to 1490mm

250mm up to 1000mm

No Restrictor

1500mm up to 3000mm

250mm up to 5000mm

75mm Ø

TOP EXIT - VERTICAL ONLY INCLUDING OFFSET

Vertical Flue Height from Top of Appliance

Restrictor Size

3000mm up to 4990mm

52mm Ø

5000mm up to 1000mm

47mm Ø

Packing Checklist

Qty Description
1

Stove

1

Flue Blanking plate

1

Coal Retainer

1

Log set (5 logs)*

1

Ash Panels (2 sections)*

1

Fixing Kit Containing
1 Instruction Manual
1 Wood Screw
1 Rawplug
1 Box spanner

*Packed in appliance

1