-12-
Model G0453Z/G0454Z (Mfg. 1/09+)
220v Single-Phase
Operation
full Load Amperage Draw
this machine draws the following amps under
maximum load:
g0453z Amp draw ............................... 15 Amps
g0454z Amp draw................................25 Amps
Power Supply Circuit Requirements
the power supply circuit for your machine Must
be grounded and rated for the amperage given
below. never replace a circuit breaker on an exist-
ing circuit with one of higher amperage without
consulting a qualified electrician to ensure compli-
ance with wiring codes.
If you are unsure about
the wiring codes in your area or you plan to
connect your machine to a shared circuit, con-
sult a qualified electrician.
g0453z Minimum Circuit size ..............20 Amps
g0454z Minimum Circuit size ...............30 Amps
SECTION 2: CIRCUIT REQUIREMENTS
Serious personal injury could occur if you
connect the machine to power before com-
pleting the setup process. DO NOT connect
the machine to the power until instructed
later in this manual.
Electrocution or fire could
result if machine is not
grounded and installed in
compliance with electrical
codes. Compliance MUST
be verified by a qualified
electrician!
Power Connection Device
the type of plug required to connect your machine
to power depends on the type of service you cur-
rently have or plan to install. We recommend
using the plugs shown in
figure 3.
Extension Cords
using extension cords may reduce the life of the
motor. instead, place the machine near a power
source. if you must use an extension cord:
•
Model g0453z: use at least a 12 gauge cord
that does not exceed 50 feet in length.
•
Model g0454z: use at least a 10 gauge cord
that does not exceed 50 feet in length.
•
Ensure that the extension cord contains a
ground wire and plug pin.
•
A qualified electrician Must size cords over
50 feet long to prevent motor damage.
Grounding Prong
Current Carrying Prongs
6-20 PLUG
GROUNDED
6-20 RECEPTACLE
figure 3. recommended connection types.
Grounding Prong
is Hooked
Current Carrying Prongs
L6-30 GROUNDED
LOCKING
RECEPTACLE
L6-30
LOCKING
PLUG
nEMA L6-30
plug & receptacle
for Models g0454z
nEMA 6-20
plug & receptacle