Troubleshooting: Filling, Heating, and Brewing (con’t.)

Tank does not
heat.

Thermostat faulty or
out of calibration.

Heater faulty.

Make sure thermostat
is turned on.

Check resistance
across elements with
wires disconnected.

Recalibrate thermostat. If no reme-
dy or thermostat does not cycle,
replace thermostat.

If resistance is much different than 7
to 10 ohms, replace heater.

Problem

Possible Cause

Service Check

Remedy

Heating Problems

The heating system consists of the following components:

• Thermostat, located on the tank or on the front of top control panel under top cover.
• Heating Element, located on top of tank under top cover.

Recovery time is very
long.

Heater faulty.

See above.

See above.

P200/RAPS200 Brewers

If you still need help, call our Service Department at (800) 568-5715, press 2 (Monday through
Friday, 8 a.m. - 6 p.m. EST) or an authorized service center in your area. Please have the model
and serial numbers ready so that accurate information can be given.

Prior authorization must be obtained from Grindmaster Technical Services Department for all
warranty claims.