GE Profile GLD4500 User Manual

Tall tub built-in dishwasher

background image

Dimensions and Installation Information (in inches)

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

As an EnErgy StAr

®

partner, gE has determined

that this product meets the

EnErgy StAr guidelines

for energy efficiency.

Specification Created 6/09

350206

Panel

Thickness

Kit

A

B

C

GPF525

25-1/4"

23-1/2"

N/A

1/4"

GPF575

25-1/2"

23-5/8"

1/4"

3/4"

Listed by

Underwriters

Laboratories

• The rough cabinet opening must be at least 24" deep,

24" wide and approximately 34-1/2" high from floor to
underside of the countertop.

4"

6"

5"

5"

4"

Figure A

Floor MUST be Even

With Room Floor

Cabinets

Square

and

Plumb

This Wall Area

must be Free

of Pipes or

wires

24"

Min.

24"

Min.

34-1/2"

Underside of

Countertop

to Floor

Plumbing and Electric Service

Must Enter Inside This Area

24

25

MAX.

20-1/2

4

4 (Adjustable)

33-3/4" MIN.

adj. to 35"

27-1/2

22

B

See Detail E for 3/4" Panel

Detail E for 3/4 panel only

Door insert

A

Back View

Front View

F
F

1-7/8

1-7/8

20

Section E-F

C

3/8

3/4

B

See Detail E for 3/4" Panel

Detail E for 3/4 panel only

Door insert

A

Back View

Front View

F
F

1-7/8

1-7/8

20

Section E-F

C

3/8

3/4

Electrical Rating
Voltage AC.......................................................... 120
Hertz..................................................................... 60
Total connected load amperage............. 10
Calrod® heater watts max........................ 875
For use on adequately wired 120-volt,
15-amp circuit having 2-wire service
with a separate ground wire. This appliance
must be grounded for safe operation.
Note: The rough cabinet opening must be at
least 24" deep, 24" wide and approximately
34-1/2" high from floor to underside of
the countertop. Dishwasher must not be
installed more than 10 feet from sink for
proper drainage. All plumbing and
electrical work must be in accordance
with local codes. The power cord and
connections must comply with the National
Electrical Code Section 422 and/or local
codes and ordinances. The cord must be no
longer than 6 ft. from the junction box to
the receptacle.
Installation Information: Before installing,
consult installation instructions packed with
product for current dimensional data.

GLD4500/50/60R

GE

®

Tall Tub Built-In Dishwasher