beautypg.com

Dbxr463gg, 0 cu. ft. extra-large capacity gas dryer – GE DBXR463G User Manual

Page 2

background image

For complete information, see installation instructions packed with your dryer.
Ducting Materials:

For best performance, this dryer should be vented with 4" diameter all rigid metal

exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-

rigid) ducting can be used (Kit WX08X10077). In special installations, it may be

necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct.

A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid

metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter

can be maintained throughout the entire length of the transition duct. Please see

installation instruction packed with your dryer for complete instructions when using

flexible metal (foil type) ducting.
Exhaust Length Calculation:

1. Determine the number of 90° turns needed for your installation. If you exhaust to the

side or bottom of dryer, add one turn.

2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated

is shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the

duct length should be treated as a 90° elbow. A turn over 45° should be treated as a

90° elbow.

Dryers

must be exhausted to the outside.

Caution: For personal safety do not terminate exhaust into a chimney, under any

enclosed house floor (crawl space), or into an attic, since the accumulated lint could

create a fire hazard or moisture could cause damage. Never terminate the exhaust

into a common duct or plenum with a kitchen exhaust, since the combination of lint

and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts,

bird nesting, etc. The wall cap must also be located at least 12" above the ground or

any other obstruction with the opening pointed down.
For more information on venting kits and accessories, please call 1-800-GE-CARES.

Special Installation Requirements
Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label

on the dryer back.

• The dryer MUST be exhausted to the outside.

• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

0" either side; 3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.

• Closet doors must be louvered or otherwise ventilated and must contain a minimum

of 60 sq. in. of open area equally distributed. If this closet contains both a washer and

a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

• The installation must conform with the local codes, or in the absence of local codes,

with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

• Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Dryer Exhausting Information : Use metal duct only, vertical and horizontal ducting.

DBXR463GG

GE

®

6.0 Cu. Ft. Extra-Large Capacity Gas Dryer

370280

Specification Revised 5/09

Best performance

Domestic

dryer models

Maximum length of 4"

dia.

rigid metal duct

Number

of

90°

turns

Exhaust hood type

A

4"

opening

B

2-1/2"

opening

7.0, 6.0 and 5.8 cu. ft.

capacity models

all gas dryers

0

1

2

3

90 ft.

60 ft.

45 ft.

35 ft.

60 ft.

45 ft.

35 ft.

25 ft.

A

4

B

2-1/2

A

This manual is related to the following products: