Specifications – GE GP94DNSRSA User Manual
Page 12
12
Operating Instructions
Safety Instructions
Consumer S
uppor
t
Tr
oubleshooting Tips
* Minimum and maximum water flow may vary slightly, depending on the temperature setting and the inlet water temperature.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.
Specifications.
Model
GN75
GN94 and GP94
Minimum Gas Consumption Btu/h
15,000
Maximum Gas Consumption Btu/h
180,000
199,000 (NG)/190,000 (LP)
Hot water capacity (Min.–Max.)*
0.6–7.5 GPM (2.3–28.5 L/min)
0.6–9.4 GPM (2.3–35.5 L/min)
Hot water capacity (35°F rise)
7.5 GPM (28.5 L/min)
9.4 GPM (35.5 L/min)
Default Temperature Setting
120°F (49°C)
(no control)
Remote Control Default
104°F (40°C)
Temperature Setting
Maximum Temperature Setting
140°F (60°C)
Minimum Temperature Setting
98°F (37°C)
Weight
Approximately 49 lbs (22 kg) Indoor Units, 46 lbs (21 kg) Outdoor Units
Noise Level
55dB (A)
Electrical
Normal
79 W
Consumption
Standby
2.8 W
Anti-Frost Protection
100 W
Minimum Gas
Natural Gas
5
″ WC
Supply Pressure
Propane
8
″ WC
Maximum Gas
Natural Gas
10.5
″ WC
Supply Pressure
Propane
13.5
″ WC
Approved Gas Type
Natural Gas or Propane – Ensure unit matches gas type it is being installed on.
Connections
Gas Supply: 3/4
″ MNPT, Cold Water Inlet: 3/4″ MNPT, Hot Water Outlet: 3/4″ MNPT
Ignition System
Direct Electronic Ignition
Electrical Connections
AC 120 Volts, 60 Hz.
Water Supply Pressure
Minimum Water Pressure: 20 PSI (Recommended 30–80 PSI for maximum performance;
full flow cannot be achieved with 20 psi inlet pressure)
Maximum Water Supply Pressure
150 PSI
Remote Control
Non-Polarized Two-Core Cable (Minimum 22 AWG)
Remote Control: DC 12 Volts (Digital)