Problem

Possible Causes

Action Required

Mixer will not run.

Bowl guard not closed.

Rotate guard to the right until fully closed.

Bowl not raised.

Raise bowl to highest position.


Timer is not engaged.

Turn timer at least fi ve minutes past “0”, then to

desired time or set time to the green “on” position.

Power not connected properly.

Check all power connections. Plug into a live socket.

(Do not use extension cord!) Test socket with

another

item.


Building circuit breaker is off.

Check breaker box.

Internal overload tripped.

SP25 & smaller models: Press stop button then

press reset button. Larger models: Wait two

minutes. Press stop button then press start button.

(If overload continues to trip, reduce batch size

and/or adjust recipe!)

Gear not engaged.

Switch gear fully into position. (Mixer will not operate

if the speed control lever is positioned in between

speeds)

Mixer stops during

Internal overload tripped.

SP25 & smaller models: Press stop button then

mixing.

press reset button. Larger models: Wait two

minutes. Press stop button then press start button.

(If overload continues to trip, reduce batch size

and/or adjust recipe!)

Damaged or broken transmission belt. SP25 & larger models: Technician to replace belt.

Speeds were changed during mixing, Return speed control lever to a speed model

SP80PL only.

position and restart the mixer.

Mixer is noisy.

Mixer is not installed on level surface. Adjust surface or relocate mixer. Make sure rubber

feet are installed.

Bowl not seated correctly or clamps

Ensure bowl is seated into bowl cradle correctly and

not in place.

bowl clamps are locked into place.


Agitator

not

fi tted properly.

Remove and attach agitator into position properly.

Overloading bowl.

Reduce batch size. (See Capacity Chart)

Damaged or worn belt.

Replace belt.

Planetary ring gear needs

Technician to inspect for source of noise.

more grease.

Reapply high-pressure grease.

Safety guard seized Clean & lubricate slide sheath.

Technician must drop down planetary to access mat

(will not move freely).

& sheath.

Agitators won’t go

Lack of lubrication and/or cleaning

Wipe planetary shaft with a clean damp cloth and

onto the planetary

of the planetary shaft.

lubricate the shaft with mineral oil or food quality

shaft easily.

grease.