Humidity Control
When using a Humidistat (normally closed), cut jumper PJ6 on the control board. The Humidistat will only affect cooling
airflow by adjusting the Airflow to 85%.

Two Stage Heating
When using staged electric heat, cut jumper PJ4 on the control board.

Thermostat Wiring
Use thermostat wiring diagram Figures 10 thru 13 and those provided with the thermostat when making these connections.

NOTE: DO NOT USE THESE DIAGRAMS FOR AEPT MODELS. SEE SUPPLEMENTAL INSTALLATION AND
OPERATING INSTRUCTIONS FOR AEPT MODELS.

ROOM THERMOSTAT

W

Y

G

R

#18 GA. 4 WIRES WITH
COOLING 3 WIRES WITHOUT

R

G

W

Y

TO CONDENSING
UNIT 24V. CONNECTIONS

#18 GA. 2 WIRES

BLUE

WHITE

GREEN

RED

CONTACTOR

COIL

AR UNIT

Figure 10 - Low Voltage Wiring Diagram for Cooling Unit with optional heat kit 10KW and below

W2

W Y G R

R

G

Y

W

GREEN

RED

WHITE

BLUE

BROWN

#18 GA. 4 WIRE WITH
COOLING 3 WIRE WITHOUT

ROOM THERMOSTAT

OUTDOOR
THERMOSTAT
(OPTIONAL)

CONDENSING
UNIT 24V. CONNECTIONS

#18 GA. 2 WIRES

#18 GA. 2 WIRES

CONTACTOR

COIL

AR UNIT

Figure 11 - Low Voltage Wiring Diagram for Cooling Unit with optional heat kit 15KW and above