3 engine governor gain adjustments – Generac 005030-0 (15kW) User Manual
Page 18

16
3.3
ENGINE GOVERNOR GAIN
ADJUSTMENTS
Engine speed governing is also controlled by the
engine control board. The engine governor has been
set by the factory during final testing of the generator
and should not be adjusted.
If, however, adjustments are necessary, the following
procedure should be followed (Figure 3.2 and Section
3.7):
1. Move DIP switch 8 to the TEST mode (OFF posi-
tion).
2. Set all three potentiometers (pots) fully counter-
clockwise.
3. Under no load condition, increase the GAIN pot
as much as possible without causing instability.
4. Apply 1/4, 1/2, 3/4 and full load to the unit.
Decrease the GAIN pot if there is instability at any
load point.
5. Under full load condition, increase the stability
pot until the unit returns to 60 Hertz (or 50 Hertz
in 50 Hertz applications).
Figure 3.2 — Control Board Dip Switch Location
Section 3 - Operation
Liquid-cooled 15, 20 and 25 kW Generators
Condition
System
Low
Low
High
Over
Over
Switch Position
Ready (Green)
Bat (Red)
Oil (Red)
Temp (Red)
Speed (Red)
Crank (Red)
Manual
Auto
Off
Generator Switch is
OFF
X
OFF
OFF
OFF
OFF
O
in the OFF Mode.
System Ready for
ON
X
OFF
OFF
OFF
OFF
O
Automatic Start
Generator Switch is
OFF
X
OFF
OFF
OFF
OFF
O
in the MANUAL Mode
Weekly Exerciser
X
Flashing
Flashing
Flashing
Flashing
Flashing
O
O
O
is not set
(-----------------------------------1 sec rate---------------------------------------)
Battery Voltage <12.2V
X
ON
O
O
O
for >1 minute
(Non-latching)
Battery Voltage <6V
OFF
ON
O
O
Unit Shutdown due
OFF
X
ON
O
O
to Low Oil Pressure
Unit Shutdown due to
High Coolant Temperature
OFF
X
ON
O
O
or Low Coolant Level
Unit Shutdown due
OFF
X
ON
O
O
to Engine Overspeed
Unit Failed to Start
OFF
X
ON
O
O
during it’s Crank Cycle
Utility Voltage is
Flashing
X
O
O
<45% of Nominal
1 sec rate
Engine Speed Signal Fault
OFF
X
Flashing
O
O
Control Board is
OFF
X
The five RED LED’s will turn on one at a time
O
O
O
in GTS Mode