Grizzly G0504 User Manual
Page 15

G0504 16" Horizontal Resaw Bandsaw
-13-
3. Remove the wiring box covers on the main
motor and elevation motor.
4. Wire the main motor and elevation motor as
shown on the diagrams on the inside of each
motor wiring box cover. (The circled refer-
ences on the diagrams represent labels on
the wires.)
Note: Figures 5 & 6 below have been pro-
vided for your reference and are current
at the time that this manual was written.
However, always use the diagram on the
wire cover that comes with your motor! Also,
the electrical system on this machine is setup
for the "RUN" diagrams shown on the wire
cover. Ignore the "START" diagrams for this
machine.
Figure 5. 30 HP main motor 440V wiring.
��
��
��
��
��
��
���������
��
��
��
Figure 6.
1
⁄
2
HP elevation motor 440V wiring.
��
��
��
��
��
��
��
��
��
��
��
��
���������
5. Replace the main motor relay (LR3D-3363
63/80A) with the relay from kit (LR3D-3357
37/50A) and set the dial to “47.”
6. Set the dial on the elevation motor relay to
"1.5."
7. Replace any wire duct covers and motor
wiring box covers you might have removed
during this procedure, and close the electrical
box door.
To avoid electrocution or
fire, ensure all wiring mod-
ifications are inspected
and approved by a quali-
fied electrician before con-
necting the machine to the
power source.