GE JKP86SH User Manual
Ge appliances, Dimensions (in inches)
GE Appliances
Specification Revised 5/04
320358
JKP86SH – GE 27" Built-In Double Microwave/Thermal Oven
Dimensions (in inches)
(Must support 275 lbs.)
6015 Built-In MW/Double Ovens
(Pub. 1-G003 pg 105B) May 12, 1993
Built-In Microwave/Double Ovens
Dimensions (in inches)
E
Minimum
cutout location
from floor
Allow minimum of
21" for clearance
to adjacent corners,
drawers, walls, etc.
21
2" X 4" or
equiv. runners
Conduit
(49" long)
Allow 3/4" for overlap
of oven over all
edges of cutout
10
A
D
Recommended
junction box
locations.
Locate junction
box either 5" MIN.
below cutout
floor or 48" MIN.
above cutout
floor
C
B
F
G
H
CL
Suitable
bracing
to support
runners
18"
Over centerline
of cabinet
2" x 4" or
equivalent
runners
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at least a 194°F
temperature rating.
Note: If marks, blemishes or the cutout opening is visible above the installed oven, it may be
necessary to add wood shims under the runners and front trim until the marks or openings
are covered.
KW Rating
240V
6.4
208V
5.1
Breaker Size
240V
30 Amps
208V
30 Amps
Cabinet
27"
A – Cabinet Width Required
27" min.
B – Minimum Cabinet Depth
23-5/8"
C – Opening Width
25" min.-25"-1/4 max.
D – Opening Height
41-1/4" max.
E – Minimum Cutout Location from Floor
22"
Oven
F – Overall Depth
23-5/8"
w/o trim
41-1/8"
G – Overall Height
with trim
42-1/8"
H – Overall Width
26-5/8"
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec
of at least a 194°F temperature rating.
Installation Information: Before installing, consult installation instructions
packed with product for current dimensional data.
R
Listed by
Underwriters
Laboratories
For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
Electric wall ovens are not approved for installation with a plug and receptacle.